Z-Wave Plus Fibaro Датчик движения
Extremely versatile 4-in-1 Z-Wave sensor combining motion, temperature, light level and vibration functions.
- PIR (motion), light level and temperature sensors and detects vibrations
- Compatible with any Z-Wave or Z-Wave Plus Controller
- Supports protected mode (Z-Wave network security mode) with AES-
128 encryption - Tamper and low-battery alarm notification
- Very small size makes it ideal for any Z-Wave system
- Z-Wave Plus Certified
FIBARO Motion Sensor is a highly advanced ultra-small, battery powered multi-sensor. This device detects movement, measures the current ambient temperature, intensity of the light and thanks to built-in accelerometer detects vibrations. FIBARO Motion Sensor is a completely wireless and mobile device. Depending on user-defined situation in the settings panel it’s eye will shine in different colours, alerting you whenever the temperature and light intensity changes, or when it detects the movement in the room. The battery can last up to 2 years while its level is automatically reported to the central unit. The notification is being sent to the central hub when the battery level approaches to critical.
Чем больше диапазон действия, тем более надежным является продукт - устройство имеет первоклассную антенну. Оптимизированное для надежности, это устройство может взаимодействовать беспроводным способом на расстояния более 150 метров.
Лучше антенна. Лучше Z-Wave. Устройство разработано на технологии Z-Wave Plus последнего 5го поколения, чтобы предоставить вам самое быстрое время отклика и оптимальное время жизни батареи между перезарядками.
Если вы используете устройство для обеспечения безопасности, вы хотите чтобы взаимодействие было защищенным. Вот почему устройство использует беспроводное шифрование AES-128 для защиты от несанкционированного доступа и хакеров.
Используете ли вы устройство для комфорта или безопасности, вы желаете чтобы оно всегда оставалось обновленным до последней версии. Как бы не создавались обновления прошивки для устройства, вы всегда можете обновить его с помощью Microsoft Windows или выбрать Z-Wave контроллер.
Technical Specification
- MODEL NUMBER
- FGMS-001
- HARDWARE
- Z-Wave Chip 500 series
- COMMUNICATION PROTOCOLS
- Z-Wave Plus
- Z-WAVE GROUPS
- Five groups and five devices (nodes)
- SENSOR
- PIR: 7m detection and 2.4m recommended installation height
- Temperature: -20 - +100°C (±0.5°C within 0°C C-40°C range))
- Light: 0 - 32,000Lux
- Accelerometer
- DIMENSIONS
- Packing size: (LxWxH)
- Base size: 45mm x 45mm x 48mm (LxWxH)
- CERTIFICATIONS
- CE, Z-Wave
- POWER SUPPLY
- CR123A battery, 3.0V DC
- POWER CONSUMPTION
- up to 1W
- RADIO SIGNAL POWER
- up to 1mW
- RANGE
- up to 150m (outdoors) and 100m (indoors)
- OPERATIONAL TEMPERATURE RANGE
- 0-40°C
- OPERATIONAL HUMIDITY:
- 80%
- IP CODE
- IP20
Package content
- Unit:
- Sensor Unit
- Back Mounting Plate
- Double-Sided Tape
- Screws (x3)
- User manual
Additional Info
Z-Wave Association Capabilities
Model: FIBARO Motion Sensor (FGMS-001)
Z-Wave Certification Number: ZC10-15050019
Group ID |
Maximum Nodes |
Description |
1 | 1 | Lifeline - report group |
2 | 5 | Trigger: Motion - association group, value depends on the configuration. |
3 | 5 | Trigger: Tamper - association group. |
4 | 5 | Trigger: Motion ZW3 - association group for ZW3 backward compatibility. |
5 | 5 | Trigger: Tamper ZW3 - association group for ZW3 backward compatibility. |
Z-Wave Configuration Capabilities
Model: FIBARO Motion Sensor (FGMS-001)
Z-Wave Certification Number: ZC10-15050019
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 2 | MOTION SENSOR’S SENSITIVITY | 8 to 255 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | BASIC COMMAND CLASS FRAMES CONFIGURATION | 1 | only the BASIC ON command frame sent in Basic Command Class. | |
2 | only the BASIC OFF command frame sent in Basic Command Class. | ||||
0 (Default) |
BASIC ON and OFF command frames sent in Basic Command Class. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 2 | BASIC ON command frame value | 0 to 255 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 2 | BASIC OFF command frame value | 0 to 255 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | ASSOCIATIONS IN Z-WAVE NETWORK SECURITY MODE | 0 to 15 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | MOTION SENSOR’S BLIND TIME (INSENSITIVITY) | 0 to 15 (Default) |
(0,5-8 seconds) Formula to calculate the time: time [s] = 0.5 x (value + 1) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | TAMPER SENSITIVITY | 0 to 121 (Default) |
(0,08 - 2g; multiply by 0,016g; 0 = tamper inactive) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 2 | TAMPER ALARM CANCELLATION DELAY | 1 to 32767 (Default) |
(1-32767 seconds) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 1 | TAMPER OPERATING MODES | 2 | Tamper and orientation in space. Three reports are sent right after tamper alarm cancellation delay time. | |
0 (Default) |
Only tamper (default) | ||||
1 | Tamper and earthquake detector. Function may be used as a simple seismograph. Two reports including the strength of shock are always sent. First, right after the detection and second (value=0) after tamper alarm cancellation delay time. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
25 | 1 | TAMPER CANCELLATION REPORTS | 1 (Default) |
Send tamper cancellation report | |
0 | Do not send tamper cancellation report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
28 | 1 | TAMPER ALARM BROADCAST MODE | 0 (Default) |
Tamper alarm reported to association groups. | |
1 | Tamper alarm reported in broadcast mode to 3rd association group. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
29 | 1 | TAMPER ALARM BROADCAST MODE | 0 (Default) |
Tamper alarm reported to association groups. | |
1 | Tamper alarm reported in broadcast mode to 5th association group. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | PIR sensor’s “PULSE COUNTER” | 0 to 3 (Default) |
(1 - 4 pulses) Formula to calculate the number of pulses: pulses = (value + 1) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | PIR sensor’s “WINDOW TIME” | 0 to 3 (Default) |
Formula to calculate the time: time [s] = 4 x (value + 1) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 2 | ILLUMINATION REPORT THRESHOLD | 0 to 32767 (Default) |
(1-32767 lux; 0=reports are not sent) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 2 | ILLUMINATION REPORTS INTERVAL | 0 to 32767 (Default) |
(1-32767 seconds; 0 = no reports) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 2 | MOTION ALARM CANCELLATION DELAY | 1 to 32767 (Default) |
(1-32767 seconds) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
60 | 2 | TEMPERATURE REPORT THRESHOLD | 0 to 225 (Default) |
(0,1-25,5[C],; 0 = reports are not sent) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
62 | 2 | INTERVAL OF TEMPERATURE MEASURING | 0 to 32767 (Default) |
(1 - 32767 seconds; 0 = temperature will not be measured) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
64 | 2 | TEMPERATURE REPORTS INTERVAL | 0 to 32767 (Default) |
(1 - 32767 seconds; 0 = no reports) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
66 | 2 | TEMPERATURE OFFSET | -1000 to 1000 (Default) |
(-100[C] – 100[C]) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | PIR SENSOR OPERATING MODE | 0 (Default) |
PIR sensor always active | |
1 | PIR sensor active during the day only | ||||
2 | PIR sensor active during the night only | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
80 | 1 | LED SIGNALING MODE | 1 to 9 | single long blink at the moment of reporting motion. No other motion will be indicated until alarm is cancelled. | |
10 to 18 (Default) |
single long blink at the moment of reporting motion and one short blink each time the motion is detected again. | ||||
19 to 26 | single long blink at the moment of reporting motion and two short blinks each time the motion is detected again. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
81 | 1 | LED BRIGHTNESS | 0 to 100 (Default) |
(1 - 100%; 0 = brightness determined by the ambient lighting - see parameters 82 and 83) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
82 | 2 | AMBIENT ILLUMINATION LEVEL BELOW WHICH LED BRIGHTNESS IS SET TO 1% | 0 to 32766 (Default) |
(0-32766 lux) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
83 | 2 | AMBIENT ILLUMINATION LEVEL ABOVE WHICH LED BRIGHTNESS IS SET TO 100% | 1 to 32767 (Default) |
(1-32767 lux) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
86 | 2 | MINIMUM TEMPERATURE RESULTING IN BLUE LED ILLUMINATION | 0 to 255 (Default) |
(0-255[C]) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
87 | 2 | MAXIMUM TEMPERATURE RESULTING IN RED LED ILLUMINATION | 0 to 255 (Default) |
(0-255[C]) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
89 | 1 | LED INDICATING TAMPER ALARM | 0 | LED does not indicate tamper alarm. | |
1 (Default) |
LED indicates tamper alarm. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 2 | NIGHT / DAY | 1 to 32767 (Default) |
(1-32767 lux) |
Z-Wave Command Classes
Model: FIBARO Motion Sensor (FGMS-001)
Z-Wave Certification Number: ZC10-15050019
Supported Command Classes |
Alarm Sensor |
Application Status |
Association |
Association Group Information |
Basic |
Battery |
Binary Sensor |
Configuration |
CRC16 Encapsulation |
Device Reset Local |
Firmware Update MD V3 |
Manufacturer Specific |
Multi-Channel-Association |
Multi-Command |
Multilevel Sensor |
Notification |
Powerlevel |
Security |
Version |
Wake Up |
ZWavePlus Info |
Controlled Command Classes |
Basic |
Технология | Z-Wave+ |
---|---|
Z-Wave Plus: | Нет |
Z-Wave аппаратная платформа | ZM5202 |
Z-Wave тип библиотеки | Enhanced 232 Slave |
Z-Wave тип устройства | Notification Sensor |
Z-Wave тип роли | Reporting Sleeping Slave |
Группы ассоциаций | 5 |
Производитель | Fibaro |
Тип датчика | мультисенсор |
Z-Wave Функции | Запуск сцен |
Внутренняя/наружная установка | Внутренняя |
Источник питания | Батарея |
Тип батареи | CR 123 |
Форм-фактор | Настенный |
Назначение | Управление освещением, Обнаружение активности, Отслеживание температуры, влажности, освещенности |
OTA обновление прошивки | Да |